Miter Cut for Water Pipeline and Hoop Stress

Just one question !!!

i am working in water pipe line project ( 28" O.D - 0.5 mm thickness - 60 bar working pressure - API 5L X52 pipes),

and now we facing a problem! big problem!!

The ASME code B31.4 - 1998 (para 4062.2) state that if the hoop stress is more than 20% of t